0142215 powerloc max power injectable infusion set without y injection site 22 gauge x 1 5 in.
Power injectable port needle.
Powerloc ez safety infusion set.
Safestep huber needle set.
Powerloc max safety infusion set.
Ez huber safety infusion set.
Port access needles power injectable.
A tactile feel an audible click and visual confirmation verifies the lockout for safe removal.
300 psi 19 gauge and 20 gauge needles with 5 ml s maximum infusion rate.
Smart port ct injectable port.
Designed for patient comfort.
Needle allows for higher pressure and flow rates for power injections with port a cath power p a c.
300 psi 22 gauge needle with 2 ml s maximum infusion rate.
The smart port ct family of power injectable ports which include low profile and mini models.
They are mri conditional at 3 tesla.
The gripper plus power p a c.
The ct engraving on all models can be seen through chest x ray or scout scan.
Miniloc safety infusion set.
As the needle is removed from the port and enters the base of the needle an orange safety shield rotates over the needle point and the needle locks into place.
This product does not contain dehp.
An injection port with a self sealing silicone septum and a radiopaque catheter.
And 300 psi pressure limit setting when used with a gripper plus huber needle.
Systems and other power injectable port systems.
Vascular access vortex ports.
Identifying a smart port power injectable port.
Implantable infusion ports can be identified subcutaneously by feeling the top of the septum and the.
Huberplus safety infusion set.
Gripper plus power p a c.
Lower insertion and penetration force than non siliconized port access needles.
It is indicated for power injection of contrast media up to 5 ml sec.
Needles provide the flexibility of use including power injection of contrast media.
Power injection is performed using a power injectable needle only.
A power port needle is specifially made to withstand the pressure used to inject the ct dye.
Angiodynamics vortex revolutionizes port design with a rounded chamber that has no sludge harboring corners or dead spaces.
The power injectable implantable infusion port device consists of two primary components.
So yes you can access a powerport with a huber needle but no if there is a chance that the patient will have a ct scan.
If the dye were to be injected into a huber needle that needle would break inside the port.
Powerloc max power injectable infusion set without y injection site 19 gauge x 1 5 in.
Bard winged infusion set.
0142015 powerloc max power injectable infusion set without y injection site 20 gauge x 1 5 in.
Powerloc safety infusion set.