Capacity 1 cop 1 mass flow rate 1 discharge temps f 1 gwp 100 year 2.
R22 refrigerant replacement r407c.
There are several refrigerants that do cause the depletion of the ozone layer and that can be used as.
Mixing r22 with r407c or any other refrigerant.
For a no oil change r 22 replacement see freon mo99.
In fact changing the refrigerant may void the u l.
Cannot be added to r 22 unless fully evacuated and recharged with 407c.
Retroļ¬ tting systems that employ compressors manu.
Replacing r 22 with freon 407c in these systems requires switching to polyolester poe oil.
Jug cylinder virgin r 22 replacement.
R22 refrigerant replacement 407c 25 lb virgin factory sealed r407c cylinder.
According to the 609 epa rule mixing refrigerants is illegal and anybody caught doing so will be heavily fined.
Since refrigerant r22 has ozone depletion potential it is use is being stopped in the phase manner.
They are not meant to replace any existing relevant standards or recommended good practice.
This article discusses various options for replacement for r22 refrigerant.
Fmi 2010 energy store development conference hfc component comparison 1 relative to r 22 standard cycle 105 f condenser 25 f evaporator 10 f of superheat subcooling 2 from the ipcc ar4 3 l sub classification under public review cond.
R407c refrigerant 25lb cylinder r 407c new usa factory sealed r22 replacement.
The following is a set of general guidelines to assist in the replacement of r22 condensing units with equivalent r407c units.
Freon 407c has been a popular r 22 replacement because of its properties which include.
Although you may this restriction is primarily political we would like to give you a basic education to explain the two most devastating effects of such action.
However once the decision has been made to make the change from r 22 to hfc r 407c the fol lowing guidelines are recommended.
Similar cooling capacity energy efficiency and pressures as r 22 in systems.
R407c r 407c refrigerant 25lb tank.
Below you can find different r22 replacement refrigerants and the of each.
All new compressors use poe oil and are compatible with r407c and most other r22 replacement refrigerants.
R407c can be used to completely replace r 22 refrigerant in new or existing r 22 residential and commercial air conditioning systems as well as non flooded evaporator chillers.
No technical reason to replace the hcfc refrigerant.
Apart from describing r22 alternative refrigerants the article also describes epa instructions for r22 replacement.
All work must be carried out by appropriately qualified refrigeration and or electrical personnel complying with local and national codes of practice.
Legacy air currently only offers r407c as our choice for an r 22 replacement refrigerant and we do carry it on our trucks.